> Using Apps > Exam Mode App (for fx-CG100)

Exam Mode App (for fx-CG100)

The Exam Mode puts some limits on calculator functions, which allows it to be used when taking an exam or test. Enter the Exam Mode only when actually taking an exam or test.

Your calculator has four* different Exam Modes.

IB (International Baccalaureate)

Portugal

United Kingdom

Texas (USA)

Select h > Exam Mode to start up the app and display the Exam Mode Manager menu.

You can use this menu to enter any one of the Exam Modes or to unlock an Exam Mode of another calculator.

CY876_Exam Mode(CG100)_App_1

You can choose from among four Exam Modes when “International” (default setting) is selected for the Country setting of the System app. If you select a different setting for Country, only the Exam Mode specific to that country and IB can be selected.

Restrictions While in an Exam Mode

Entering an Exam Mode affects calculator operation as described below.

Some of the apps and functions are disabled. For more information, refer to the help that appears when you perform the operation below.

  1. On the Exam Mode Manager menu, select [Exam Mode Help] > [Apps & Functions].

  2. This displays a menu for selecting Exam Mode type.

    CY876_Exam Mode(CG100)_Restrictions_1
  3. Select the Exam Mode whose restrictions you want to view and then press O.

The calculator will back up user data (main memory) when you enter an Exam Mode. Backed-up data will be restored when you exit the current Exam Mode. Data you created while in an Exam Mode is deleted when you exit the mode.

The information below applies to the Python app operations.

You can enter up to five characters for a py file name.

You can use single-byte numeric and alphabetic characters (lowercase only) for a py file name.

py files are stored in the calculator’s main memory.

The “Memory ERROR” message appears when main memory capacity is low. If this happens, delete any unnecessary files in order to increase available free space.

Only the settings below are saved before entering an Exam Mode.
Angle, Complex Mode, Display, Fraction Result, ‎  π‎ Result, ‎x10Square BKey, Show Option Numbers, FORMAT Key, pinned input history, Q1Q3 Type, Language, Country, Battery Settings
However, some are forced to change as shown below while in an Exam Mode.

System app’s Auto Power Off setting: Always “‎60 Min.‎”

System app’s User Name and Organization entries: Always blank

Both of the above items are restored to their previous settings when you exit the Exam Mode.

Important!

Replacing batteries with a set of fresh ones is recommended before using an Exam Mode.

In an Exam Mode, the backlight brightness level will change to the darkest setting automatically if you do not perform any operation on the calculator for about 30 seconds. Note that in an Exam Mode the backlight will not turn off, so battery power runs down faster. Exit the Exam Mode as soon as possible after you get through using it.

Entering an Exam Mode

  1. h > Exam Mode

  2. This displays the Exam Mode Manager menu.

  3. Highlight [Enter Exam Mode] and then press O.

  4. From the menu that appears, select the Exam Mode you want to enter.

  5. Press O.

  6. This displays the “Enter Exam Mode?‎” dialog on the calculator.

  7. Press O.

  8. If, in step 3 of this procedure, you select any Exam Mode besides IB, a warning dialog will appear at this time. To continue with the operation and enter the Exam Mode you selected in step 3, select [OK]. If you are about to take an IB exam, select [Cancel] to return to step 3, and then select IB.

    CY876_Exam Mode(CG100)_Entering _1

    After displaying the message Entering Exam Mode.‎ for about three seconds, the calculator enters the Exam Mode you selected in step 3 above and displays the Exam Mode Manager menu.

    CY876_Exam Mode(CG100)_Entering _2

Exam Mode Calculator Operations

Exam Mode screens are identified by a boundary around the screen and a flashing icon in the upper right corner. The color of the boundary and the icon type depend on the Exam Mode.

Exam Mode

Boundary Color

Icon

IB

Green

Exam Mode R

Portugal

Blue

Exam Mode P

United Kingdom

Magenta

Exam Mode R

Texas (USA)

Cyan

Exam Mode T

The flashing interval of the icon slows down about 15 minutes after you enter an Exam Mode.

In an Exam Mode, the Auto Power Off trigger setting is fixed at approximately 60 minutes.

Selecting [Elapsed Time] on an Exam Mode Manager menu causes the dialog box shown below to appear. The dialog box shows the elapsed time in an Exam Mode.

CY876_Exam Mode(1AU)_Calculator Operations _1

You can restart the elapsed time count by performing one of the operations below.

Press the RESTART button.

Remove the calculator’s batteries.

Delete Main Memory data.

If you are already in an Exam Mode, re-enter it.*

If you are already in one Exam Mode you will not be able to enter the other Exam Mode. To change to the other Exam Mode, exit the current Exam Mode and then enter the other one.

The table below shows how certain operations affect the Exam Mode.

If you do this:

The calculator stays in the Exam Mode.

Data input in the Exam Mode is retained.

Turn power off and then back on again

Yes

Yes

Press the RESTART button

Yes

No

Remove the calculator’s batteries

Yes

No

Delete Main Memory data

Yes

No

Re-entering the Exam Mode You are Currently In

You can re-enter an Exam Mode even if you are currently in an Exam Mode. Doing so discards any data you input and settings you configured while currently in the Exam Mode and returns them to what they were when you first entered the Exam Mode.*

The only settings retained is the Battery Settings in the System app.

  1. While in an Exam Mode, highlight [Re-Enter Exam Mode] and then press O.

  2. This displays the “Re-Enter Exam Mode‎?‎” dialog on the calculator.

  3. Press O.

  4. After the message “Re-Entering Exam Mode.‎” is displayed for about three seconds, the calculator automatically restarts and re-enters the Exam Mode.

Exiting an Exam Mode

There are three ways to exit an Exam Mode.

(1) Exiting an Exam Mode by Connecting to a Computer

  1. Use a USB cable*1 to connect the calculator that is in an Exam Mode to a computer.

  2. This displays the “Select Connection Mode” dialog on the calculator.

  3. Highlight [USB Flash / Unlock Exam Mode] and then press O.

  4. The message “Preparing USB” will appear on the calculator screen. Stand by and do not perform any operation on the calculator.

    The screen shown to the right appears when a connection is established between the calculator and the computer.

    CY875_Exam Mode_Exiting _1
  5. On the computer, open the calculator drive.

  6. On the computer, copy or delete any file that is on the calculator drive.

  7. On the computer, terminate the connection between the calculator and computer.

  8. Terminating a connection automatically causes the calculator to restart. This causes the calculator to exit an Exam Mode and return to the state it was in before the Exam Mode was entered.

Use of a genuine CASIO USB cable is recommended. If you plan to use a commercially available USB cable, be sure to use a cable that can transfer data.

(2) Exiting an Exam Mode by Allowing 12 Hours to Elapse

Approximately 12 hours after entering an Exam Mode, turning on the calculator will cause it to exit the Exam Mode automatically.

Important!

If you press the RESTART button or if you replace batteries before turning on the calculator, it will re-enter the Exam Mode when turned on, even if 12 hours have elapsed.

(3) Exiting an Exam Mode by Connecting to another Calculator

  1. On the calculator that is in an Exam Mode (Calculator A), display the Exam Mode Manager menu.

  2. Use a 2.5mm plug cable*2 to connect Calculator A to another calculator that is not in an Exam Mode (Calculator B).

  3. On Calculator A, highlight [Unlocked Exam Mode] and then press O.

  4. On Calculator B, select h > Exam Mode, highlight [Unlock Exam Mode] and then press O.

  5. When the “Complete!‎” message appears on Calculator B, Calculator A automatically restarts. Calculator A exits an Exam Mode and the data on Calculator A returns to the state it was in before the Exam Mode was entered.

Included in the optionally-available SB-2000 package (USB cable and 2.5mm plug cable).

Note

You can also connect your calculator to another calculator model that has an exam mode and unlock your calculator’s Exam Mode from the other model or unlock the other model’s exam mode from your calculator.
For details about the required operation on the other model, see the information below.

Exam Mode Manager menu’s [Exam Mode Help] > [How to Exit]

User’s documentation of the other calculator model