Accuracy:
±15 seconds per month average when time adjustment by communication with a phone is not possible.
Basic Functions:
Analog
Hour, minute (moves every 10 seconds), second
Digital
Hour, minute, second, month, day, day of the week
p.m. (P), 24-hour timekeeping
Full Auto Calendar (2000 to 2099)
Digital Compass:
Measurement range: 0° to 359°
Measurement Units: LCD: 1°, Analog: 6°
Continuous Bearing Measurement (1 minute)
North Indication Hand
Bearing calibration (2-point calibration, figure 8 calibration, magnetic declination calibration)
Auto bearing calibration
Altimeter (relative altitude):
Measuring range: -700 to 10,000 m (or -2,300 to 32,800 ft.)
Display range: -3,000 to 10,000 m (or -9,840 to 32,800 ft.)
(Altitude calibration can be used to display any 10,700 m within the range above.)
Measuring unit: 1 m (or 5 ft.)
Auto measurement interval (2 minutes, 5 seconds)
Altitude calibration
Altitude graph
Altitude differential measurement (-100 to +100 m/-1,000 to +1,000 m (or -325 to +325 ft./-3,280 to +3,280 ft.))
Altitude Memory
(Manually recorded data: Up to 14 records of altitude, year, month, day, and time recorded with the press of a button; Auto recorded data: One record of high altitude, low altitude, cumulative ascent, cumulative descent)
Barometer:
Measurement range: 260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display range: 260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Measurement unit: 1 hPa (or 0.05 inHg)
Barometric pressure graph
Barometric pressure indicator (-10 to +10 hPa/-1 to +1 hPa (or -0.25 to +0.25 inHg/-0.05 to +0.05 inHg))
Barometric Pressure Change Indications
Temperature:
Measuring range: -10.0 to 60.0 °C (or 14.0 to 140.0 °F)
Display range: -10.0 to 60.0 °C (or 14.0 to 140.0 °F)
Measuring unit: 0.1 °C (or 0.2 °F)
Temperature Correction
Sensor Accuracy:
Direction sensor
Measurement accuracy: Within ±10°
(Guaranteed accuracy temperature range: 10 °C to 40 °C (50 °F to 104 °F))
Bearing hand indication: Within ±2 gradations
Pressure sensor
Measurement accuracy: Within ±3 hPa (0.1 inHg)
(Altimeter measurement accuracy: Within ±75 m (246 ft.))
- Guaranteed accuracy temperature range: -10 °C to 40 °C (14 °F to 104 °F)
- Strong impact or prolonged exposure to temperature extremes may negatively affect accuracy.
Temperature Sensor
Measurement accuracy: Within ±2 °C (3.6 °F)
(Guaranteed accuracy temperature range: -10 °C to 60 °C (14 °F to 140 °F))
Pedometer:
Step count measurement using a 3-axis accelerometer
Step count display range: 0 to 999,999 steps
Step count reset: Auto reset at midnight each day
Step count accuracy: ±3% (According to vibration testing)
Power Saving
Sunrise/Sunset Functions:
Sunrise and sunset times
Day select
Stopwatch:
Measuring units: 1/100 seconds (first hour); 1 second (after first hour)
Measuring capacity: 23:59’59” (24 hours)
Measurement functions: Elapsed time, split times
Timer:
Setting unit: 1 minute
Countdown range: 1 minute to 24 hours
Countdown unit: 1 second
Time up alert duration: 10 seconds
Alarm:
Time alarms
Number of alarms: 5
Setting units: Hours, minutes
Alarm tone duration: 10 seconds
Hourly time signal: Beep every hour on the hour
World Time:
Current time in 38 cities (38 time zones), and UTC (Coordinated Universal Time) time
Auto summer time setting
Swapping with Home City
One-touch UTC display
Mobile Link:
Auto Time Adjustment
Time setting adjusted automatically at preset time.
One-touch Time Correction
Manual connection and time adjustment
Phone finder
Watch operation sounds the alert sound of the phone.
World Time
A selection of more than 300 World Time cities
Auto Daylight Saving Time (summer time) switching
Automatic switching between standard time and summer time.
Mission Log
Recording of waypoints and their altitudes
Location Indicator
Shows the bearing and distance to a location registered on the watch.
Auto altitude calibration
Automatic altitude calibration at a preset time
Timer Settings
Alarm Settings
Mode sort sequence and number of modes setting
Timekeeping Mode display item setting
Altimeter settings
Barometer settings
Compass settings
Step count data transfer
Calories burned calculation (speed information + altitude information)
Hand alignment correction
Communication Specifications
Bluetooth®
Frequency band: 2400 MHz to 2480 MHz
Maximum transmission power: 0 dBm (1 mW)
Communication range: Up to 2 meters (depends on environment)
Other:
High-brightness DOUBLE LED light (Auto Light, afterglow); illumination duration setting; low battery alert; operation tone ON/ OFF; hand shift feature
Power Supply:
CR2025 x 1
Battery life: Approximately 2 years
Conditions
Auto Time Adjustment: 4 times/day
Alarm: Once (10 seconds)/day
Illumination: Once (1.5 seconds)/day
Direction readings: 60 seconds continuous, 20 times/month
Climbs: 1/month
- Altitude Measurement
Every second for 3 minutes + every 5 seconds for 57 minutes
- Barometric Pressure Change Indications
Every second for 3 minutes + every 2 minutes for 23 hours and 57 minutes
- Mission Log Measurement
Every 2 minutes for 12 hours
- Location Indicator Measurement
10 times for 3 minutes each
Step counting: 12 hours/day
Auto bearing calibration measurements: 10 times/day
Barometric pressure graph measurements: 12 times/day
Specifications are subject to change without notice.